Floor Load Width Explained

Floor Loads

Floor Loads

4 Floor Load Width Flw Youtube

4 Floor Load Width Flw Youtube

How To Build A Deck Step One Softwoods Pergola Decking Fencing Carports Roofing

How To Build A Deck Step One Softwoods Pergola Decking Fencing Carports Roofing

Beam Design

Beam Design

Structural Design Concepts For The Home Inspector Internachi

Structural Design Concepts For The Home Inspector Internachi

Understanding Loads And Using Span Tables Building And Construction Technology Umass Amherst

Understanding Loads And Using Span Tables Building And Construction Technology Umass Amherst

Understanding Loads And Using Span Tables Building And Construction Technology Umass Amherst

Floor load width flw 78.

Floor load width explained.

A room used solely for sleeping might need to carry only 30 psf whereas a garage floor over a basement would need 50 psf or higher. Example flw floor if x 2000mm load width y 4000mm a 900mm flw a x 2 a flw a 1900mm flw b x y 2 flw b 3000mm flw c y 2 flw c 2000mm 79. Floor loads whether the bearers are supporting load bearing walls or only floor loads the area of the floor supported by an individual bearer must be determined. An inaccessible attic space on the other hand might have a live load of only 20 psf.

This is referred to as the floor load width flw. In both instances the floor load width is equal to the sum of half of the total span on either side of the bearer total span 4m floor load width 2m for a visual representation of the floor load width see the sketch below. Where the bearer supports load bearing walls the type of roof covering also needs to be determined. A typical wood frame floor covered with carpet or vinyl flooring has a dead load of about 8 pounds per square foot.

The load producing the greatest stress in a framing member is the governing load for that member. If there s wall board covered ceiling suspended from the underside of that floor the dead load increases to about 10 pounds per square foot. Critical reinforcement beam stress and deflection conditions occur based upon maximum wheels loads for the floor beams joists spaced less than 8 0. The dead load on a floor is determined by the materials used in the floor s construction.

Drywall attached to the underside of this system is not expected to crack when the floor joist system deflects 1 3. For an office building the live load is normally a uniform load of 50 pounds per square foot psf over the entire floor area for a framing member or a 2 000 pound load placed upon any 2 1 2 x 2 1 2 square foot space. The load is an average value. First floor live loads have higher requirements than second floor live loads 40 pounds per square foot vs.

How To Load Calculation On Column Beam Wall Slab

How To Load Calculation On Column Beam Wall Slab

1 2 Structural Loads And Loading System Engineering Libretexts

1 2 Structural Loads And Loading System Engineering Libretexts